3.6
Wiring the Operator Arm(s) for Push To Open
1. Locate the wiring terminal board on the bottom of the
operator arm(s).
2. Wire the operator arms according to the diagram below.
NOTE: 1 indicates Master arm or Single operator connections, 2 indicates Slave arm if ap-
plicable and is not used in single gate installations.
The main difference with Push To Open is the matching of column 1 with
column 6 in the chart above. Note how the FCCs no longer match up and
the FCAs don’t either, also the power leads are swapped.
Wiring Connections for Operator Arm Power.
Position
from right
in arm
Color
Inside
Arm
Arm to Board
Wire Color
Terminal
Purpose
Board
Terminal
Block
Board Connection
Terminal
M Blue Blue/White
Lg. Wire
Power CN2 CHM1 (master)
CHM2 (slave - if dual)
M Brown Brown/White
Lg. Wire
Power CN2 APM1 (master)
APM2 (slave - if dual)
COM Blue Blue
Sm. Wire
Limit
Common
CN3 COMF (For both master
and slave- if dual)
FCC Brown Brown
Sm. Wire
Limit
Open
Position
CN3 FCA1 (master)
FCA2 (slave - if dual)
FCA Black Black
Sm. Wire
Limit
Closed
Position
CN3 FCC1 (master)
FCC2 (slave - if dual)