Determine Run Time
4.2
Once you complete the first run, press the button and actuate your gate
a few times. When the gate stops on the limits: If the gate has stopped
short of or further than desired position, adjust the limit switches:
After you have your limits in the correct position secure the position of
the switches with the screws and run your gate through a few cycles. On
the display you will see a count while the arms are moving. This is your
run time. Record your run time below.
Actual Run Time: _____________________________
Note: The above example is for Pull-To-Open operation. If
you are installing your gate opener as Push-To-Open then
the open limit will be reverse of the above.