Find Limit Positions
E-S 500 / 502 Classic Series Instruction Manual
4.1
1. Manually release the gate and move the gate to the desired closed
position.
2. Take a metal washer and drag it along the side of the grey shaft until it is
attracted by the internal magnet.
3. Move the limit switch on the bottom to line up with the washer.
Underneath the arm there are slides secured with Philip head screws. After
loosening the screws the switches will be able to slide. (picture of limits on
next page)
4. Move the gate to the open
position and repeat with the open
limit switch (as you open the gate
you can leave the washer on the
side and it will move along with the
magnet).
Example of washer and magnet in closed
position (open for push-to-open)
Example of washer and magnet in open position
(closed for push-to-open)