Control Board Overview
E-S 500 / 502 Classic Series Instruction Manual
5.6
!
CAUTION! Do not run 110V AC power direct to the
board. This will cause permanent damage to both
boards and void your warranty. Caution!
Lamp
Terminal:
Sends pulses of 24VDC during opening and closing
to be used with a 24VDC lamp.
E_Lock:
Sends a pulse (length of time determined by P6
parameter) of 24VDC for a solenoid gate lock during
opening.
A second 1 second pulse of power will be sent after
the closed limit switch is reach to assist in relocking
the gate lock.
Magnetic gate lock must be powered separately
and this terminal can be used to activate a relay that
cuts power to the magnetic lock at the beginning of
a cycle.
V+/
Photocell/
GND:
Provides 12V to be used with a photocell for gate
safety. The photocell terminal is a Normally Closed
connection it must be jumped to GND when not
being used.
The power output on this terminal is very minimal, do
not exceed one accessory or 300 milliamps.
Do not attach accessories until after you have the gate
opener limit switches and parameters set up and the gate
opener functioning properly by remote.